Power Lines Detection and Vectorization
Menu: Analyze / Catenary detection
The Lines tab offers three methods for detecting power lines:
Manual Selection
: Select two points to create a line, which will be detected as a power line.
Semi-Automatic Detection
: Select a point, and the module will detect and vectorize nearby power lines.
Fully Automatic Detection
: Detect and vectorize all power lines using predefined classification classes.
Once a power line is detected and vectorized, you can:
Select and visualize it.
Modify its color and attributes.
Edit and refine detected lines as needed.
Classify manually detected lines as power lines
Adjust detection parameters via the Settings menu to better match your dataset.
To refine power line detection, the following parameters can be adjusted:
Detection Parameters
✔ Min. segment length – Defines the minimum segment length that will be detected.
✔ Max. segment length – Defines the maximum segment length allowed for detection.
✔ Max. Z distance – Controls the maximum allowable vertical deviation between detected segments.
✔ Max. XY distance – Limits the horizontal distance considered for pole detection.
✔ Search radius – Determines the area in which the algorithm searches for other power lines.
✔ Min. distance between lines – Prevents detecting excessive lines within a small area.
Classify Parameters
✔ Class – Defines the classification category for detected power lines or poles (e.g., Bridge Deck, Conductor Phase, Poles).
✔ Radius – Sets the classification influence area, determining the tolerance around detected objects.
Distance by Ground
✔ Min. distance – Sets the minimum clearance distance between power lines and the ground.
✔ Step – Defines the distance interval at which clearance measurements are taken.
✔ Ground classes – Specifies which ground class (e.g., Class 2 - Ground) will be used as the reference for clearance calculation.